Catalogue

Microgrid in a container

VentureGrid

A complete microgrid, delivered in one container.

VentureGrid brings together in one 20-ft container the battery, the power conversion, the distribution switchboard, an isolation transformer and the control system (EMS). Inputs for solar and the generator and feeders to the loads are built in, each with its own breaker: on site, you simply connect them, with no extra low-voltage wiring. The whole site is completed in 7 to 10 days.

Two models: VentureGrid 125 (125 kW, 261 kWh) and VentureGrid 250 (250 kW, 522 kWh). The system forms the grid itself, restarts on its own after a total blackout and coordinates panels, battery and generator: it powers a site with no grid, or backs up a grid-connected site with an optional automatic transfer switch.

  • Off-grid site: mine, island, farm, village
  • Backup for critical loads — factory, hospital, telecom site — with an automatic transfer switch
  • Extra capacity on a constrained grid connection, without reinforcement
  • Storing surplus solar, exporting the rest to the grid
VentureGrid 20-ft container, front view, mesh doors over the storage units

Configure

The configuration and what it delivers.

charge · discharge

Reference

Manufacturer reference: VentureProMG-250

Energy
522 kWh
Power
250 kW
Ratio
2.1 h

The ratio, in one line: power × duration = energy. A 2-hour system stores twice its power, a 4-hour system four times. For the same energy, a longer ratio needs less conversion power — and targets other revenue.

Datasheet (PDF)

Specifications

Technical specifications.

The two models

 VentureGrid 125VentureGrid 250
Nominal energy261 kWh522 kWh
Nominal power125 kW250 kW
Maximum apparent power137.5 kVA275 kVA
Nominal current (400 / 480 V)180 / 150 A360 / 300 A
Solar input, made to measure50 – 150 kW150 – 300 kW
Load feeders, made to measure50 – 150 kW150 – 300 kW
Generator input, made to measure50 – 100 kW100 – 200 kW
Weight (approx.)9.1 t12.5 t

Battery

Chemistry
Lithium iron phosphate (LFP)
Cells
3.2 V / 314 Ah
Nominal voltage
1,000 V DC
Voltage range
680 – 1,000 V DC
Service life
≥ 8,000 cycles at 0.5 P, 25 °C

Grid-tied and off-grid

Voltage
400 V (340 – 440 V) · 480 V (410 – 530 V)
Frequency
50 / 60 Hz (47 – 53 / 57 – 63 Hz)
AC system
3P + N + PE
Current distortion
< 3 %
Power factor
−1 to +1
Off-grid overload
110 % continuous, 120 % for 1 min
Functions
Grid forming, black start, parallel operation

Installation

Format
20-ft high-cube container
Dimensions (L × W × H)
6,058 × 2,438 × 2,896 mm
Ingress protection
IP 54
Operating temperature
−30 to 55 °C
Isolation transformer
400/400 V · 480/480 V
Display
Rack-mount KVM console
EMS protocols
Modbus · IEC 61850 · IEC 60870-5-104
Control
Local and remote (cloud)

We size it with you.

The grid connection, the contract, the generation already in place: three facts are enough to know whether this range is the right one. If not, we point you to another.

See the other ranges